Lift Air Supply: Check Pressure at the Machine, Not Just the Compressor
For a lift configuration that requires compressed air, assess the supply at the equipment inlet under the agreed operating conditions. Workshop buyers need the selected lift’s requirements and the actual distribution layout; a compressor gauge alone cannot approve the bay.

Key takeaways
• Confirm whether the ordered lift configuration requires air before assessing the workshop network.
• Compressor pressure and pressure available at the machine are different measurements.
• A complete air specification identifies pressure, demand, connection and air-quality requirements.
• Agree the equipment-side connection and commissioning responsibilities before installation.
1. Start with the ordered pneumatic configuration
The 6010B/6010C record lists electric lock release as standard and pneumatic release as an order option. Therefore an air-supply review belongs to the selected pneumatic version, not automatically to every lift in this family. The 6010B is rated at 3,000 kg with 1,000 mm maximum lifting height; the 6010C is rated at 4,000 kg with 1,200 mm maximum lifting height.
BH6108 provides a different example. Its record describes a recessed alignment lift with 4,000 kg main capacity and an integrated 3,000 kg secondary stage. The documentation shows a pneumatic cylinder, while the configuration expressly leaves compressed-air requirements to the selected version. Neither its capacity nor its 2.2 kW motor establishes the air specification.
For both enquiries, identify the quoted configuration first. The current verified records do not publish numerical air pressure or consumption requirements. This guide explains how to assess the supply once the equipment provider supplies those requirements; it does not invent them.
2. Compare pressure at the equipment inlet with the required conditions
A compressor gauge describes pressure at its own location. It does not establish what reaches the lift after the workshop distribution system. Atlas Copco’s working-pressure guidance explains that piping, connections, filters and dryers can introduce losses between the compressor and the user.
For lift procurement, the practical application is to define where the required pressure applies. Ask the lift provider to identify the equipment inlet and the required operating conditions there. Then have the air-system provider assess that point, including the actual connecting arrangement.
A pressure figure without its measurement location and conditions is an incomplete acceptance criterion. Do not turn an idle gauge reading elsewhere in the building into approval for the selected pneumatic release.
3. Include other air users in the workshop assessment
A shared air network serves more than the new lift. List the equipment that may draw air at the same time, its location and available demand information. Atlas Copco notes that changing demand can cause temporary pressure dips; that is why an assessment needs the demand pattern as well as a nominal pressure.
For a hypothetical workshop, a lift and a nearby pneumatic tool may share one branch. A satisfactory reading while the tool is idle does not demonstrate the same conditions during the intended combination of work. This is a planning scenario, not a claim about the air consumption or fault response of either EHRLE model.
Ask the qualified providers to agree representative commissioning conditions. Do not diagnose a release problem by repeatedly operating a loaded lift or compensate by increasing pressure beyond the equipment’s documented limits.
4. Treat the final hose and couplings as part of the supply
The last connection is part of the air path, not merely a purchasing detail. Atlas Copco’s piping guide specifically includes flexible hoses, couplings and fittings when assessing pressure losses. A suitable main network does not by itself establish that every final connection suits the intended user.
For the quotation, define the connection interface, supplied components and the boundary between the lift package and site work. The current EHRLE records do not establish a universal connector thread, hose bore or hose length. Those details must match the approved configuration.
For a BH6108 recessed layout, coordinate the documented service route before civil work. For a pneumatic-option 6010B or 6010C, coordinate the connection with each approved working position. Neither example authorizes moving the equipment under load or altering factory pneumatic circuits.
5. Resolve air quality separately from pressure
Pressure is not an air-quality specification. The piping reference discusses condensate separation alongside distribution losses and leakage. For an equipment purchase, the separate question is what air condition the selected pneumatic components require at the inlet.
Ask the lift provider to specify any required filtration, moisture limits and lubrication conditions, and identify any supplied preparation components. The current records do not establish a filter grade, dew point, oil requirement or maintenance interval for these configurations. Do not assume an airline lubricator is required, or add oil because another workshop tool uses it.
Keep the confirmed requirements in the same equipment schedule as the pressure and connection data. A compressor or treatment-system label alone does not replace the lift-side requirements.
6. Make the handover decision about the complete connection
A useful handover record ties the delivered lift configuration to the agreed inlet requirements and the site provider’s verification. Identify the documents used, the equipment-side measurement point, the agreed operating conditions and any unresolved item. This is a proposed procurement record, not a substitute for the model’s commissioning procedure.
Keep air-supply suitability separate from vehicle compatibility and foundation acceptance. Correct utilities do not establish that a vehicle fits the platforms or that a recessed installation meets its drawing. If the lift or air connection changes, review the affected requirements instead of relying on an earlier approval for a different arrangement.
Your pre-order air-supply checklist
Confirm:
1. Exact lift model and whether the quoted version requires compressed air.
2. Documented inlet pressure range and the conditions under which it must be maintained.
3. Air-demand information, including its units and reference conditions.
4. Inlet interface, connecting components and supplier/site-work boundaries.
5. Required air quality and any supplied preparation equipment.
6. Site network assessment, representative demand conditions and commissioning responsibility.
Send EHRLE the proposed 6010B/6010C pneumatic option or BH6108 configuration, the intended bay positions and available workshop air-system information. Ask for the missing lift-side values before purchasing a compressor upgrade or committing to a connection layout.
Frequently asked questions
Does this guide give a universal lift air-pressure setting?
No. The current verified records do not establish one. Use the selected configuration’s documented inlet requirements.
Does an electric-hydraulic drive prove that no air connection is needed?
No. Drive mode and an optional pneumatic release describe different functions. The 6010 family’s standard electric release and pneumatic option must be distinguished.
Can the compressor gauge alone approve my bay?
No. The assessment must address the specified equipment inlet and agreed operating conditions, including the connecting arrangement.
Should I increase compressor pressure if release operation seems wrong?
Do not use pressure changes as an improvised repair. Follow the supplied fault instructions and have qualified providers assess the equipment and supply within documented limits.
Sources and image notes
Published, enabled and verified EHRLE 6010B/6010C and BH6108 records were checked on 11 November 2026; related product pages appear below. Primary external references: Atlas Copco, How to determine the ideal working pressure for your air compressor, and How to size compressed air piping?, at atlascopco.com. These support distribution losses, changing demand, final connections and condensate considerations. Their general engineering guidance is applied here to a procurement review; no compressor setting, pipe size or numerical air requirement is assigned to EHRLE.
Cover and gallery are existing product scene illustrations, not customer installations or pneumatic connection diagrams. The cover shows the 3T 6010 configuration; neither image establishes a supplied release option, connector or air-treatment package. The shared-branch workshop example is hypothetical.